Starter Coordination

Type 1 and Type 2 coordination schemes to guarantee the protection of contactors and relays against short circuit currents.

13 rows

Coordination SetupStandardShort-Circuit Behavior
T1IECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
T2IECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
TCIECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
TSDIECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
TSSIECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
TVFDIECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
TATIECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
TPWIECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
UL2NECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
ULSSNECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
ULVFDNECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
ULSDNECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.
ULATNECVerified contactor + overload relay + short-circuit protective device coordination per IEC 60947-4-1 / UL 508E.

Save this calculation and export it as a PDF with the Vexten app.Google PlayApp Store

Questions

What technical specifications does the starter coordination table include?

Type 1 and Type 2 coordination schemes to guarantee the protection of contactors and relays against short circuit currents. It compiles 13 reference entries organized across Coordination Setup, Standard and Short-Circuit Behavior for fast lookup during design and field maintenance.

How do you look up and select the right rating in starter coordination?

Locate the target coordination setup in the first column (spanning from T1 through ULAT) or type any designation, size, or rating into the search bar above to filter matching rows instantly.

What practical factors should you check when applying starter coordination data?

Confirm that the protective device clears both sustained overloads and bolted faults within the conductor thermal withstand time while maintaining bonding continuity and upstream selectivity.