Thyristor / Diode Conduction Power Dissipation

On-state conduction power losses calculated from threshold voltage and forward slope resistance.

P =—

Enter your values to calculate instantly.

P = VT₀ · Iavg + rT · Irms²

Save this calculation and export it as a PDF with the Vexten app.Google PlayApp Store

Share this calculation

WhatsApp

How it’s calculated

P=VT0⋅Iavg+rT⋅Irms2P = VT_{0} \cdot I_{\mathrm{avg}} + rT \cdot I_{\mathrm{rms}}^{2}
P
Thyristor / Diode Conduction Power Dissipation · W / kW / MW / mW
VT0
Threshold Voltage · V / kV / MV / mV
rT
Dynamic On-State Resistance · Ω / kΩ / MΩ / GΩ
Iavg
Branch Average Current · A / kA / mA / µA
Irms
Branch RMS Current · A / kA / mA / µA

Questions

What is the formula for thyristor / diode conduction power dissipation and what does each variable mean?

The governing equation is P = VT₀ · Iavg + rT · Irms², solving for P from VT0 (threshold voltage, V), rT (dynamic On-State resistance, Ω), Iavg (branch average current, A) and Irms (branch RMS current, A). On-state conduction power losses calculated from threshold voltage and forward slope resistance.

Which input and output units can you select for thyristor / diode conduction power dissipation?

Every parameter includes metric and imperial unit selectors: VT0 [V, kV, MV, mV, µV]; rT [Ω, kΩ, MΩ, GΩ, mΩ, µΩ]; Iavg [A, kA, mA, µA]; Irms [A, kA, mA, µA]. The solver normalizes all scales automatically before evaluating the equation and lets you switch the output P across W, kW, MW, mW, HP, CV, BTU/h, TR.

When is the thyristor / diode conduction power dissipation formula used in electrical engineering?

Normalize all unit prefixes before solving, keep actual power dissipation below 50–60 % of component power ratings for thermal reliability, and account for standard manufacturing tolerances.