How it’s calculated
- Tnom
- Servomotor Rated Torque from Power & RPM · N·m / lb·ft / lb·in / kgf·m
- P
- Rated Power · W / kW / MW / GW
- N
- Rated Speed · RPM / rad/s / Hz
Questions
What is the formula for servomotor rated torque from power & RPM and what does each variable mean?
The governing equation is Tnom = P / ω = (P · 60) / (2π · N), solving for Tnom from P (rated power, W) and N (rated speed, RPM). Rated continuous shaft torque derived from electrical power and nominal speed.
Which input and output units can you select for servomotor rated torque from power & RPM?
Every parameter includes metric and imperial unit selectors: P [W, kW, MW, GW, HP, CV, BTU/h, TR]; N [RPM, rad/s, Hz]. The solver normalizes all scales automatically before evaluating the equation and lets you switch the output Tnom across N·m, lb·ft, lb·in, kgf·m, kN·m.
When is the servomotor rated torque from power & RPM formula used in electrical engineering?
Distinguish mechanical shaft output from electrical input power by accounting for efficiency and power factor, and allow for locked-rotor starting inrush when sizing feeders and protection.