Skip to main content

Recommended Lux Levels

Recommended illuminance (lx) and glare limits (UGR) for 22 spaces.

22 rows

Space / Visual TaskIlluminance (Em)Max UGRMin CRI (Ra)
General Office (Workstations)300 - 500 lx (optimal 500 lx for computer screens)less than or equal to 19 (prevents fatigue during long work sessions)CRI greater than or equal to 80
Drafting & Technical Drawing Rooms750 - 1000 lx (optimal 750 lx for manual drafting)less than or equal to 16 (strict glare control)CRI greater than or equal to 90 (high color fidelity)
Conference & Board Rooms300 - 400 lx (dimmable for presentations)less than or equal to 19 (prevents screen reflections)CRI greater than or equal to 80
Classrooms & Lecture Halls300 - 500 lx (300 lx minimum, 500 lx for boards/workshops)less than or equal to 19 (critical for student concentration)CRI greater than or equal to 80
Operating Theatres & Surgeries1,000 lx general | 10,000 - 20,000 lx surgical cavityless than or equal to 19 (absolute glare control on surgical lamp)CRI greater than or equal to 90 (R9 red index is critical for tissues)
Hospital Patient Rooms100 lx (general) | 300 lx (medical exam) | 5 lx (night)less than or equal to 19 (prevents glare for recumbent patients)CRI greater than or equal to 80 (90 for medical exam)
Retail Showrooms & Boutiques500 - 750 lx (up to 1500 lx for accent lighting)less than or equal to 22CRI greater than or equal to 85 (90+ for fashion or commercial art)
Residential Kitchens (Task Areas)150 lx general | 300 lx on countertops and cutting areasless than or equal to 22CRI greater than or equal to 80 (critical to assess food freshness)
Residential Living Areas100 - 150 lx (300 lx for reading task areas)less than or equal to 22CRI greater than or equal to 80 (promotes a natural environment)
Fine Electronic Assembly Lines750 - 1000 lx (high visual precision demand)less than or equal to 19 (prevents glare on shiny metal components)CRI greater than or equal to 80 (critical for wire coding and resistor marking)
Heavy Machining & Metal Workshops300 - 500 lx (300 lx general, 500 lx on lathes/milling machines)less than or equal to 22 (prevents fatigue near moving machinery)CRI greater than or equal to 80 (allows detection of metal defects)
Industrial Warehouses & Dispatch Centers100 - 150 lx in aisles | 200 - 300 lx in packing areasless than or equal to 25CRI greater than or equal to 60 (80 in label-reading areas)
Electrical Substation Control Rooms500 lx (optimal for mimic panels and instrumentation)less than or equal to 19 (prevents reflections on meter glass)CRI greater than or equal to 80
Public Roads & Highways15 - 30 lx (or luminance of 1.0 - 2.0 cd/m²)N/A (Threshold Increment TI less than or equal to 10% for glare control)CRI greater than or equal to 20 (HPS) | CRI greater than or equal to 70 (modern LED)
Bedrooms & Residential Rooms100 - 150 lx (50 lx minimum for rest, 150 lx for reading)less than or equal to 19 (prevents glare when lying down)CRI greater than or equal to 80 (optimal 90 for quality rest)
Bathrooms & Vanity Areas100 lx general | 300 - 500 lx at the vanity mirrorless than or equal to 22 (prevent mirror reflections)CRI greater than or equal to 90 at vanity (accurate skin tones)
Design & Architecture Studios500 lx general | 750 - 1000 lx on drafting tables or easelsless than or equal to 16 (maximum reflection control)CRI greater than or equal to 90, with high R9 value (superior color fidelity)
Library Stacks & Archives200 lx general | 150 lx vertical on book spinesless than or equal to 19CRI greater than or equal to 80
Underground Parking Garages75 lx general | 150 lx on ramps, corners, and crossingsless than or equal to 25 (prevent glare from metallic surfaces)CRI greater than or equal to 70 (critical to distinguish signs and vehicles)
Sports Stadiums & Playing Fields200 lx training | 500 - 750 lx competition | 1000 - 2000 lx HDTV broadcastingless than or equal to 22 (strict glare control along athlete line of sight)CRI greater than or equal to 70 (80+ with high R9 for television)
Perimeter Security Lighting10 - 20 lx on perimeters | 50 lx at checkpoints and gatesN/A (intrusive glare is prioritized toward intruders as a deterrent)CRI greater than or equal to 60 (70+ for CCTV facial recognition)
Loading Docks & Dispatch Areas150 lx on the dock | 50 lx in the outdoor maneuvering yardless than or equal to 25CRI greater than or equal to 70 (critical for barcode and label reading)

Save this calculation and export it as a PDF with the Vexten app.Google PlayApp Store

Questions

What technical specifications does the recommended lux levels table include?

Recommended illuminance (lx) and glare limits (UGR) for 22 spaces. It compiles 22 reference entries organized across Space / Visual Task, Illuminance (Em), Max UGR and Min CRI (Ra) for fast lookup during design and field maintenance.

How do you look up and select the right rating in recommended lux levels?

Locate the target space / visual task in the first column (spanning from General Office (Workstations) through Loading Docks & Dispatch Areas) or type any designation, size, or rating into the search bar above to filter matching rows instantly.

What practical factors should you check when applying recommended lux levels data?

Include a light-loss maintenance factor for lumen depreciation and dirt, check spacing-to-mounting-height uniformity, and leave at least 20 % thermal headroom on LED power supplies.