Skip to main content

Buck Inductor Peak-to-Peak Ripple Current (ΔIL)

Peak-to-peak current ripple in energy storage inductor of step-down converter.

ΔIL =—

Enter your values to calculate instantly.

ΔIL = ((Vin - Vout) · D) / (fs · L)

Save this calculation and export it as a PDF with the Vexten app.Google PlayApp Store

Share this calculation

WhatsApp

How it’s calculated

ΔIL=((Vin−Vout)⋅D)/(fs⋅L)\Delta IL = ((V_{\mathrm{in}} - V_{\mathrm{out}}) \cdot D) / (fs \cdot L)
ΔIL
Buck Inductor Peak-to-Peak Ripple Current · A / kA / mA / µA
Vin
Input Voltage · V / kV / MV / mV
Vout
Output Voltage · V / kV / MV / mV
fs
Switching Frequency · kHz / Hz / MHz / GHz
L
Choke Inductance · µH / nH / mH / H

Questions

What is the formula for buck inductor Peak-to-Peak ripple current and what does each variable mean?

The governing equation is ΔIL = ((Vin - Vout) · D) / (fs · L), solving for ΔIL from Vin (input voltage, V), Vout (output voltage, V), fs (switching frequency, kHz) and L (choke inductance, µH). Peak-to-peak current ripple in energy storage inductor of step-down converter.

Which input and output units can you select for buck inductor Peak-to-Peak ripple current?

Every parameter includes metric and imperial unit selectors: Vin [V, kV, MV, mV, µV]; Vout [V, kV, MV, mV, µV]; fs [kHz, Hz, MHz, GHz]; L [µH, nH, mH, H]. The solver normalizes all scales automatically before evaluating the equation and lets you switch the output ΔIL across A, kA, mA, µA.

When is the buck inductor Peak-to-Peak ripple current formula used in electrical engineering?

Normalize all unit prefixes before solving, keep actual power dissipation below 50–60 % of component power ratings for thermal reliability, and account for standard manufacturing tolerances.